API 16D BOP closing unit with accumulator bottles for blowout preventer stack

API 16D BOP Control Units

API 16D BOP closing units — the hydraulic power source for ram and annular blowout preventer stack operation. Electric and air-driven pump configurations with accumulator bottles sized to BOP stack closing volume requirements per API 53. Remote panel and driller's console with manual override capability. Pre-charged nitrogen accumulators for fail-safe closure during power loss. OEM manufacturer with factory acceptance testing (FAT) and on-site commissioning support included.

Specifications

SpecificationValue
Working Pressure3,000 – 5,000 PSI (hydraulic)
Accumulator Capacity80 – 640 Gallon
Pump TypeElectric Triplex / Air-Driven
StandardAPI 16D, API 53
Control StationsDriller + Remote (2-station standard)
Accumulator Pre-ChargeNitrogen, 1,000 PSI
Power Supply460V / 3-Phase / 60Hz or 380V / 50Hz
StandardAPI 16D / API 53
CategoryBlowout Preventers & Manifolds
Request Quote
WhatsApp